< img height="1" width="1" style="display:none" src="https://www.facebook.com/tr?id=1914171349308139&ev=PageView&noscript=1" />
ritop brings pp fume hoods and drug cabinets to analytica china 2026-1

News

Home >  News

Ritop Brings PP Fume Hoods and Drug Cabinets to analytica China 2026

Time: 2026-11-16

Ritop Brings PP Fume Hoods and Drug Cabinets to analytica China 2026

Jinhua Ritop Steel Cabinet Co., Ltd., a laboratory furniture supplier based in Zhejiang, is running its P2 PP fume hood, a two-person drug cabinet and a wall of lab safety cabinets at analytica China 2026 in Shanghai, 16 to 18 November, Booth 1546. Every fume hood on the stand is live, so visitors can take the anemometer reading at the sash themselves and watch the face velocity hold.

PP fume hood on the Ritop booth at analytica China 2026 in Shanghai

The P2 PP fume hood on the Ritop stand at analytica China 2026, with safety cabinets fitted below the worktop.

What Runs at Booth 1546

Four product groups carry the stand this year.

Product on the stand What visitors can do Where it fits
P2 PP fume hood Measure face velocity live through the open sash Strong-acid digestion, trace-metal work
Drug cabinet Try the dual-credential lock and read the access log Hospital pharmacy, veterinary and university stores
Lab safety cabinet Open the self-closing door, check the spill sump and vents Flammable liquid and corrosive storage
All-steel lab bench Walk a full bench run with sinks and reagent shelves General, analytical and teaching benches

Why Acid Work Is Pushing Buyers Toward Polypropylene

The questions arriving at the booth have changed. Three years ago most overseas buyers opened with a request for a steel fume hood and a better coating. This year the first question is often whether the working chamber can be polypropylene, because the chemistry in the room has moved: hydrochloric, nitric and hydrofluoric acid digestions, solvent-heavy extraction, and trace-metal analysis where a trace of iron ruins the result.

A coated steel fume hood is still the right answer for general chemistry, and we build plenty of them. But once the acid load is constant, the coating turns into a maintenance item and the buyer ends up paying for recoating every few years. Polypropylene removes that cycle, because the chamber, the liner and the worktop are the same material and there is no interface to fail.

The second shift sits in controlled drugs. Hospital pharmacies, veterinary clinics and university stores are now asked to document not only where narcotics are kept but who opened the cabinet, when, and on whose authority. A lock alone no longer satisfies that question. The record does.

The P2 PP Fume Hood: Airflow Before Material

Visitors spend the longest time at the P2, mainly because we let them measure it instead of describing it.

  • Face velocity held at 0.3 to 0.5 m/s. A streamlined gas collection chamber behind the baffle keeps airflow even across the working opening, without the corner eddies that let vapor escape from a conventional hood. The PP fume hood is built to the ASHRAE 110 containment standard, and the live demonstration shows a handheld anemometer holding steady across the sash width instead of spiking at the center.
  • A one-piece polypropylene body. The chamber uses 8 to 10 mm polypropylene sheet, cut on CNC and welded into a single shell with a seamless inner wall. No panel joint is left for acid to creep into, the surface resists strong acids, alkalis and organic solvents, and it wipes clean with no coating to damage.
  • Control that watches the sash. The touch controller tracks airflow and sash height together. Open the sash past its working limit, or let airflow drift, and the PP fume hood raises an audible and visual alarm instead of quietly losing containment. An optional variable-air-volume mode follows sash position, which our own comparison puts at roughly 30% less energy than a constant-volume fume hood.
PP fume hood sash and seamless polypropylene liner at analytica China 2026

Inside the P2 PP fume hood: sash, seamless liner and the hazard-marked base unit.

Sizes, worktop options and ducting configuration for each fume hood are listed on the PP fume hood product page.

The Drug Cabinet: Two Keys, Two People, One Log

The ductless medicine cabinet on the stand addresses the audit question rather than the storage question, and it is the piece hospital buyers return to twice.

  • Dual authorization. An electronic code and a mechanical key are linked, so the drug cabinet door opens only when both credentials are presented by two different people. No single member of staff can reach the contents alone.
  • Tiered accounts and a trail. Administrators issue accounts at different authority levels, and every opening of the drug cabinet is written to a log with time and user, which is the record narcotics and psychotropic drug rules expect.
  • A body that resists force. Double-layer cold-rolled steel is welded as one frame, with a reinforced door frame and anti-pry hinges, finished in epoxy powder coating.
  • Movement alarm. A vibration sensor raises an audible and visual alarm on prying or impact, and an optional network output pushes the alarm to a monitoring point.
Ductless medicine cabinet and flammable liquid safety cabinet on the Ritop booth

The ductless medicine cabinet and a flammable liquid safety cabinet, side by side on the booth.

Configuration and interior options for the PP drug cabinet are on the product page.

Hazardous Chemical Storage Cabinet: Fire, Leak and Vapor Control

The yellow and blue cabinets flanking the PP fume hood apply the same logic to flammable liquids.

  • Double-wall steel with an air gap. The cavity between the walls slows heat transfer and delays flame penetration, and the door returns itself under spring tension so a fire cannot hold it open. The design follows NFPA 30 and OSHA flammable storage requirements.
  • A spill sump in the base. A one-piece tray catches the contents of a failed container instead of letting liquid run across the floor.
  • Flame-arresting vents. Both sides carry vents fitted with flame arresters and can be tied into external exhaust, so vapor that builds inside a hazardous chemical storage cabinet leaves in a controlled direction.
  • Three-point locking. The rods engage together for a tight seal, the epoxy powder coating is antistatic and chemical resistant, and shelves adjust to suit different container heights.

Capacity and door options for the flammable liquid safety cabinet range are listed separately.

Lab Safety Cabinet Range for Acid and Alkali

Strong corrosives need a different enclosure from solvents, and buyers who run both usually want them side by side. The lab safety cabinet range is offered in two finishes for that reason: phosphated electrostatic powder coating for general chemical storage, and a one-piece PP body for hydrochloric, nitric and sulfuric acid service, where a coated steel panel would be the first thing to fail. Every lab safety cabinet in the range keeps the spill sump, the grounding terminal for static discharge, the three-point lock and the convection vent that balances internal pressure.

All-Steel Lab Benches and the EPC Package

Behind the hoods, the stand carries a full bench run: steel frames with adjustable feet, a phenolic worktop, reagent shelves on service posts, and base units with drawers, cupboards and sinks. The all-steel lab bench remains the default for general and analytical benches, and the same run can be built in PP, stainless steel, steel-wood or wood, so the all-steel lab bench you see is one option in a five-material range.

All-steel lab bench on the Ritop booth at analytica China 2026

The all-steel lab bench run on the stand, with reagent shelves on service posts.

The bench sits beside the hood for a practical reason. Most projects we quote this year are turnkey laboratory fits rather than single cabinets: the buyer needs the hoods, the storage, the all-steel lab bench, the sinks and the ducting in one package with one installation plan. Because the workshops sit in the same group, that package comes from one supplier instead of three, and the drawing handed to the contractor already matches the equipment.

What Buyers Can Take Away From the Stand

  • A live airflow test. Bring a reagent list and we run the fume hood with the sash at working height while you take the reading yourself.
  • Show pricing and priority scheduling. Project quotations confirmed at the show are booked into the production queue ahead of standard lead time.
  • Layout and compliance support. A whole-room plan, drawing development and environmental compliance advice are provided at no charge for the duration of the show.
  • Catalogs and case books. Visitors who register receive the product catalog and a collection of completed domestic laboratory projects.
  • Channel discussions. Distributors and contractors can work through territory, OEM supply and project pricing on site.

FAQ

Can a PP fume hood replace a steel one?

For constant strong-acid work, yes, and it removes the recoating cycle. For general chemistry with solvents and light acids, a coated steel fume hood is usually the cheaper choice, and we build both.

What face velocity should a fume hood hold?

The P2 PP fume hood is set to work between 0.3 and 0.5 m/s, and the controller alarms if the reading drifts outside that band or the sash stays above its working height.

Does the drug cabinet satisfy narcotics record keeping?

The dual-credential lock, tiered accounts and automatic opening log are designed to give an inspector a complete record of who opened the drug cabinet and when.

Why buy a lab safety cabinet from one supplier with the hood?

Because the hood, the hazardous chemical storage cabinet and the bench share a footprint in the same room. Ordering them together means one drawing, one delivery and one installation sequence.

Get Your Quote at Booth 1546

The stand is open from 16 to 18 November at Booth 1546 in Shanghai. If you cannot attend, the same support applies by message: send the room size, the chemicals in use and the equipment list, and we will return a configuration, a layout drawing and a quotation. Contact our team to start.

As a laboratory furniture supplier working with distributors, contractors and end users, we would rather quote a room than a box, and the show is the fastest place to begin that conversation. Ask for the PP fume hood, the drug cabinet or the full bench run and we will price the three together.

PREV : None

NEXT : Ritop participate in the 2026 China Import and Export Fair

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000